{ "currentVersion": 11.5, "cimVersion": "3.5.0", "id": 67, "name": "High Voltage Attachment", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkid": 102704, "latestWkid": 26852, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -119097700, "falseY": -96454900, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "spatialReference": { "wkid": 102704, "latestWkid": 26852, "vcsWkid": 105703, "latestVcsWkid": 6360, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -119097700, "falseY": -96454900, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 66, "name": "Electric Junction" }, "subLayers": [], "minScale": 500, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "ASSETTYPE", "defaultSymbol": { "type": "esriPMS", "url": "e81273a688131c8e59a15552b1adf484", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAA4AAAAOCAYAAAAfSC3RAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA+klEQVQokaWRMQqDQBBFp9gDiLa5hIWNhQcIBIscIZ1FsMgBtna3lK1cCARiFbCKYJUr7A0sbAOC2IdJsmGN2RTJL4d5zJ//Cfwo8j4Iw3A9juPSnCmlDgBwsYK+72+CIKBpmi7MuRAiZoztAGA/AxGKoohSSheO40xcZFnmAQBnjIGGibaHlz5BH+AeAKo7iD+hPRuklSSJ1zTNSin1AH8R+Rvse7T+Xb2xQ3RPeZ7HnHPP9mfbtlDX9XUYhpN58SKlxJ54URSY3gwqy/IqhNh2XXeeWMV+pJTgui7H9Ex7eOkJHWc/ahh7wsjNIdrTl2wgqsKeLPm8dAPXynTfTMaXIQAAAABJRU5ErkJggg==", "contentType": "image/png", "width": 10, "height": 10, "angle": 0, "xoffset": 0, "yoffset": 0 }, "defaultLabel": "Other", "uniqueValueGroups": [ { "heading": "Asset Type", "classes": [ { "label": "Unknown", "description": "Unknown", "symbol": { "type": "esriPMS", "url": "0842b60cbca9d8dc2115dffea0b436a2", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "0" ] ] }, { "label": "AC Overhead", "description": "AC Overhead", "symbol": { "type": "esriPMS", "url": "092ffcd21f255e1325309062a02b93cb", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "1" ] ] }, { "label": "AC Underground", "description": "AC Underground", "symbol": { "type": "esriPMS", "url": "a2bb0081c83620925c6064f58546fea1", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "2" ] ] }, { "label": "DC Overhead", "description": "DC Overhead", "symbol": { "type": "esriPMS", "url": "6bf6b0d6c9b3b0d48010f52e91c55a98", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "3" ] ] }, { "label": "DC Underground", "description": "DC Underground", "symbol": { "type": "esriPMS", "url": "a9e1df018bdce68020b71d60c5ee1e3b", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "4" ] ] }, { "label": "AC Riser", "description": "AC Riser", "symbol": { "type": "esriPMS", "url": "2e842a92f837e65998d7d28f2c207b22", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "5" ] ] }, { "label": "DC Riser", "description": "DC Riser", "symbol": { "type": "esriPMS", "url": "70b10b83932b2c89ea79663a67bb79f8", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABIAAAASCAYAAABWzo5XAAAACXBIWXMAAA7EAAAOxAGVKw4bAAABs0lEQVQ4jb2UL0hDURTGfwN9gqgwXvBPUsOaBrG4YJm2xc0kaBCGGMcMRoNFXjCaVFhzCGoyGHVFFLQZpkVBcBhsMyjf9V29b3sOg3jKg7tzfpz7fd9dB39UHf8BGgIGgS7AAxrAK/AI1H8D6gWGAb/p3AvP/BB4E8JjQYKMmaF8McXETJqBkSm6+1K8Neo8P1Qpr+9ycaLeNHBuYc0gbeKxsjXFdH4jyRMTHKHvZeesXxscz1LayVIJCuwHt8BkCIuApIlvNpnOb4xyzdL7KvqqcgS80M9mYo9arrgNWJjmHl2QhEXX0QYuxJbOS+8LLCeuIDO/yH6wFs5FQHIHaaLrNENcWIYypz1zKUfXyNXkChJWze0qqd87vYirLkjqe3JHwkqTtvXWsFlqcU3Z8GWx3JGwcZvVGKdCEZ7vqs5cBKTE+iYnpZ2s3JGwSQdmIIni5zZnB8fhcb0ZpINXE7ZKUJDFcidD+QtmNhGkehiE1tsn0xJIxT4dNhVk8anckbAm2XdVs8k35D5ObCuckjppmj9zElcW8vV44x6thdnXb3LivH4Nm+u41e5vRM0tAz/VByhVohIknz1pAAAAAElFTkSuQmCC", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "6" ] ] }, { "label": "AC Submersible", "description": "AC Submersible", "symbol": { "type": "esriPMS", "url": "981dd7f6a1082ae23980db3f2dce8592", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABIAAAASCAYAAABWzo5XAAAACXBIWXMAAA7EAAAOxAGVKw4bAAABzUlEQVQ4jb2UP0tCURjGH/xztTIcLggaRoFIEU03KB0bQ/oAUeDmF4iGFm9LWx8gaYgIwamovYYgaXBySLKhwhQEwRCSlCQeOSfOvZo0RO9y4XDeH+/7PM+5LvxRuf4DFAIQBOABoAHoAGgBqAJo/AY0CWAGgG4718SZLoBFAR8KImSRTebcRjQRXI5HJqZifvd4tNPrNp7b9fxO8ej4vHbHu3EAtxJmB3ES7cTYjm1Nr+7XnB7kxgKoubxIvNd1w+FOnK2kE3v3pymzlH0AsCRgFhA10TkJIQXNj5S+AH5Zpj+C0OcHLuoFpOc3DwFIGPuqKojCgutwEhUiq+r0YD1g4LVyhdTsWtIsZXdFnwVEd0BNuI4dosIyvjCSvW5U0dWyGl0BhaUmo6rm8kJzuC2uqiCqr9EdCktNRlWn15VZGnCN2dBpMd2hsFzDXkbnDelmGeV2Pa/0WUBMrM6c0GK6Q2GrCowQs/nYnyb7cn0pjht2EA9aDBtzQovpTsYX7mvC4iSE5Co3B8J6+WQGAsnYx8WlFC1O9rpRCksA1+EkCuRJNtpBFI5JXeJlkZNhJSHfj3fYo5Uw+fr7OVFeP5v766g16jfCywMNP9UXeEvDyffdkUwAAAAASUVORK5CYII=", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "7" ] ] }, { "label": "DC Submersible", "description": "DC Submersible", "symbol": { "type": "esriPMS", "url": "a9e1df018bdce68020b71d60c5ee1e3b", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "8" ] ] } ] } ], "uniqueValueInfos": [ { "symbol": { "type": "esriPMS", "url": "0842b60cbca9d8dc2115dffea0b436a2", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "0", "label": "Unknown" }, { "symbol": { "type": "esriPMS", "url": "092ffcd21f255e1325309062a02b93cb", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "1", "label": "AC Overhead" }, { "symbol": { "type": "esriPMS", "url": "a2bb0081c83620925c6064f58546fea1", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "2", "label": "AC Underground" }, { "symbol": { "type": "esriPMS", "url": "6bf6b0d6c9b3b0d48010f52e91c55a98", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "3", "label": "DC Overhead" }, { "symbol": { "type": "esriPMS", "url": "a9e1df018bdce68020b71d60c5ee1e3b", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "4", "label": "DC Underground" }, { "symbol": { "type": "esriPMS", "url": "2e842a92f837e65998d7d28f2c207b22", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "5", "label": "AC Riser" }, { "symbol": { "type": "esriPMS", "url": "70b10b83932b2c89ea79663a67bb79f8", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "6", "label": "DC Riser" }, { "symbol": { "type": "esriPMS", "url": "981dd7f6a1082ae23980db3f2dce8592", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "7", "label": "AC Submersible" }, { "symbol": { "type": "esriPMS", "url": "a9e1df018bdce68020b71d60c5ee1e3b", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "8", "label": "DC Submersible" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 210, 255 ], "toColor": [ 216, 252, 210, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 243, 182, 252, 255 ], "toColor": [ 243, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 201, 194, 255 ], "toColor": [ 252, 201, 194, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 223, 252, 255 ], "toColor": [ 179, 223, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 229, 187, 255 ], "toColor": [ 252, 229, 187, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 234, 215, 252, 255 ], "toColor": [ 234, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 187, 252, 248, 255 ], "toColor": [ 187, 252, 248, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 187, 188, 252, 255 ], "toColor": [ 187, 188, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 187, 220, 255 ], "toColor": [ 252, 187, 220, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 237, 252, 182, 255 ], "toColor": [ 237, 252, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 191, 252, 179, 255 ], "toColor": [ 191, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 241, 252, 255 ], "toColor": [ 212, 241, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 199, 207, 252, 255 ], "toColor": [ 199, 207, 252, 255 ] } ] } }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.symbolrotation", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 1979712.4670004405, "ymin": 174037.4177064687, "xmax": 2144650.1300378432, "ymax": 332896.29693689046, "zmin": -1.0000000474974513E-4, "zmax": 16.404200000004494, "mmin": -9.999E35, "mmax": -9.999E35, "spatialReference": { "wkid": 102704, "latestWkid": 26852, "vcsWkid": 105703, "latestVcsWkid": 6360, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -119097700, "falseY": -96454900, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "heightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "supportsVCSProjection": true, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "attachmentid", "isEnabled": true }, { "name": "globalid", "fieldName": "globalid", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "att_name", "isEnabled": true }, { "name": "contentType", "fieldName": "content_type", "isEnabled": true }, { "name": "size", "fieldName": "data_size", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "attachmentid", "type": "esriFieldTypeOID", "alias": "attachmentid", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "globalid", "type": "esriFieldTypeGlobalID", "alias": "globalid", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "att_name", "type": "esriFieldTypeString", "alias": "att_name", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "content_type", "type": "esriFieldTypeString", "alias": "content_type", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "data_size", "type": "esriFieldTypeInteger", "alias": "data_size", "editable": true, "nullable": false, "length": 4, "domain": null } ], "supportsAttachmentsResizing": true, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayFieldExpressionInfo": { "expression": "domainName($feature, 'assettype') + ': ' + $feature.assetid", "title": "AssetType and ID" }, "displayField": "SUBNETWORKNAME", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "ASSOCIATIONSTATUS", "type": "esriFieldTypeSmallInteger", "alias": "Association status", "domain": { "type": "codedValue", "name": "UtilityNetworkElectric_6_AssociationStatus", "description": "Indicates how the feature participates in associations.", "codedValues": [ { "name": "None", "code": 0 }, { "name": "Container", "code": 1 }, { "name": "Structure", "code": 2 }, { "name": "Content", "code": 4 }, { "name": "Content and Container", "code": 5 }, { "name": "Content and Structure", "code": 6 }, { "name": "Attachment", "code": 8 }, { "name": "Attachment and Container", "code": 9 }, { "name": "Attachment and Structure", "code": 10 }, { "name": "Attachment and Content", "code": 12 }, { "name": "Attachment and Content and Container", "code": 13 }, { "name": "Attachment and Content and Structure", "code": 14 }, { "name": "Visible Content", "code": 16 }, { "name": "Visible Content and Container", "code": 17 }, { "name": "Visible Content and Structure", "code": 18 }, { "name": "Visible Content and Attachment", "code": 24 }, { "name": "Visible Content and Attachment and Container", "code": 25 }, { "name": "Visible Content and Attachment and Structure", "code": 26 }, { "name": "Connectivity", "code": 32 }, { "name": "Connectivity and Container", "code": 33 }, { "name": "Connectivity and Structure", "code": 34 }, { "name": "Connectivity and Content", "code": 36 }, { "name": "Connectivity and Content and Container", "code": 37 }, { "name": "Connectivity and Content and Structure", "code": 38 }, { "name": "Connectivity and Attachment", "code": 40 }, { "name": "Connectivity and Attachment and Container", "code": 41 }, { "name": "Connectivity and Attachment and Structure", "code": 42 }, { "name": "Connectivity and Attachment and Content", "code": 44 }, { "name": "Connectivity and Attachment and Content and Container", "code": 45 }, { "name": "Connectivity and Attachment and Content and Structure", "code": 46 }, { "name": "Connectivity and Visible Content", "code": 48 }, { "name": "Connectivity and Visible Content and Container", "code": 49 }, { "name": "Connectivity and Visible Content and Structure", "code": 50 }, { "name": "Connectivity and Visible Content and Attachment", "code": 56 }, { "name": "Connectivity and Visible Content and Attachment and Container", "code": 57 }, { "name": "Connectivity and Visible Content and Attachment and Structure", "code": 58 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ISCONNECTED", "type": "esriFieldTypeSmallInteger", "alias": "Is connected", "domain": { "type": "codedValue", "name": "UtilityNetworkElectric_6_IsConnected", "description": "Indicates if the feature is connected to a subnetwork controller.", "codedValues": [ { "name": "False", "code": 0 }, { "name": "True", "code": 1 }, { "name": "Unknown", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "CREATIONDATE", "type": "esriFieldTypeDate", "alias": "Creation date", "length": 8, "domain": null }, { "name": "CREATOR", "type": "esriFieldTypeString", "alias": "Creator", "length": 255, "domain": null }, { "name": "LASTUPDATE", "type": "esriFieldTypeDate", "alias": "Last update", "length": 8, "domain": null }, { "name": "UPDATEDBY", "type": "esriFieldTypeString", "alias": "Updated by", "length": 255, "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "Global ID", "length": 38, "domain": null }, { "name": "assetid", "type": "esriFieldTypeString", "alias": "Asset ID", "length": 64, "domain": null }, { "name": "nominalvoltage", "type": "esriFieldTypeInteger", "alias": "Nominal Voltage (L-L)", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "maxvoltage", "type": "esriFieldTypeInteger", "alias": "Maximum Operating Voltage (L-L)", "domain": { "type": "codedValue", "name": "Electric_Combined_Maximum_Voltage", "description": "Combined Maximum Voltage Values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1.1 mV", "code": 1100000 }, { "name": "1.2 mV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasesnormal", "type": "esriFieldTypeSmallInteger", "alias": "Phases Normal", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasescurrent", "type": "esriFieldTypeSmallInteger", "alias": "User Assigned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasessummer", "type": "esriFieldTypeSmallInteger", "alias": "Summer Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phaseswinter", "type": "esriFieldTypeSmallInteger", "alias": "Winter Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasesplan", "type": "esriFieldTypeSmallInteger", "alias": "Planned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasesenergized", "type": "esriFieldTypeSmallInteger", "alias": "Phases Energized", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "phasefrequency", "type": "esriFieldTypeSmallInteger", "alias": "Phase Frequency", "domain": { "type": "codedValue", "name": "Electric_System_Frequency", "description": "Valid Frequencies for Phase", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 hz", "code": 50 }, { "name": "60 hz", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "numphasesconstructed", "type": "esriFieldTypeSmallInteger", "alias": "Num Phases Built", "domain": { "type": "codedValue", "name": "Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "Lifecycle_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Proposed and Approved", "code": 3 }, { "name": "Under Construction", "code": 4 }, { "name": "Approved and Under Construction", "code": 6 }, { "name": "Proposed, Approved and Under Construction", "code": 7 }, { "name": "In Service", "code": 8 }, { "name": "In Service and Under Construction", "code": 12 }, { "name": "In Service, Under Construction, and Approved", "code": 14 }, { "name": "In Service, Under Construction, Approved and Proposed", "code": 15 }, { "name": "To Be Retired", "code": 16 }, { "name": "In Service and To Be Retired", "code": 24 }, { "name": "Abandoned", "code": 32 }, { "name": "In Service, Proposed, and Abandoned", "code": 41 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "installdate", "type": "esriFieldTypeDate", "alias": "Install Date", "length": 8, "domain": null }, { "name": "retireddate", "type": "esriFieldTypeDate", "alias": "Retired Date", "length": 8, "domain": null }, { "name": "inservicedate", "type": "esriFieldTypeDate", "alias": "In-Service Date", "length": 8, "domain": null }, { "name": "spatialsource", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Source", "domain": { "type": "codedValue", "name": "Spatial_Source", "description": "Source of the spatial location", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "As-Built", "code": 1 }, { "name": "CAD", "code": 2 }, { "name": "Digitized", "code": 3 }, { "name": "GPS/GNSS", "code": 4 }, { "name": "Field Sketch", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "spatialconfidence", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Confidence", "domain": { "type": "codedValue", "name": "Spatial_Confidence", "description": "Confidence in the accuracy of the spatial data", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High", "code": 1 }, { "name": "Medium", "code": 2 }, { "name": "Low", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "grounding", "type": "esriFieldTypeSmallInteger", "alias": "System Grounding", "domain": { "type": "codedValue", "name": "Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "notes", "type": "esriFieldTypeString", "alias": "General Notes", "length": 2000, "domain": null }, { "name": "symbolrotation", "type": "esriFieldTypeSmallInteger", "alias": "Symbol Rotation", "domain": { "type": "range", "name": "Symbol_Rotation", "description": "Valid range of degrees for rotation", "range": [ 0, 359 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "maintby", "type": "esriFieldTypeSmallInteger", "alias": "Maintained By", "domain": { "type": "codedValue", "name": "Asset_Manager", "description": "The manager of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ownedby", "type": "esriFieldTypeSmallInteger", "alias": "Owned by", "domain": { "type": "codedValue", "name": "Asset_Owner", "description": "The owner of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 }, { "name": "City Dept", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SUBNETWORKNAME", "type": "esriFieldTypeString", "alias": "Subnetwork name", "length": 2000, "domain": null }, { "name": "SUPPORTEDSUBNETWORKNAME", "type": "esriFieldTypeString", "alias": "Supported subnetwork name", "length": 2000, "domain": null }, { "name": "SUPPORTINGSUBNETWORKNAME", "type": "esriFieldTypeString", "alias": "Supporting subnetwork name", "length": 2000, "domain": null }, { "name": "x_coordinate", "type": "esriFieldTypeSmallInteger", "alias": "Easting Bearing", "domain": null }, { "name": "y_coordinate", "type": "esriFieldTypeSmallInteger", "alias": "Northing Bearing", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_50", "fields": "GLOBALID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "GDB_453_SUBNETWO", "fields": "SUBNETWORKNAME", "isAscending": true, "isUnique": false, "description": "" }, { "name": "GDB_453_SUPPORTE", "fields": "SUPPORTEDSUBNETWORKNAME", "isAscending": true, "isUnique": false, "description": "" }, { "name": "GDB_453_SUPPORTI", "fields": "SUPPORTINGSUBNETWORKNAME", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S19_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "UtilityNetworkElectric_6_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Attachment", "description": "High Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "DC Overhead", "code": 3 }, { "name": "DC Underground", "code": 4 }, { "name": "AC Riser", "code": 5 }, { "name": "DC Riser", "code": 6 }, { "name": "AC Submersible", "code": 7 }, { "name": "DC Submersible", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 1, "name": "High Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Connection_Point", "description": "High Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 20 }, { "name": "AC Tap", "code": 21 }, { "name": "DC Overhead Splice", "code": 22 }, { "name": "DC Tap", "code": 23 }, { "name": "AC Busbar Tap", "code": 24 }, { "name": "DC Busbar Tap", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 2, "name": "High Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Line_End", "description": "High Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 41 }, { "name": "DC Overhead", "code": 42 }, { "name": "AC Busbar Terminator", "code": 45 }, { "name": "DC Busbar Terminator", "code": 46 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 3, "name": "High Voltage Line End" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Attachment", "description": "Medium Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead", "code": 60 }, { "name": "Underground", "code": 61 }, { "name": "Riser", "code": 62 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 7, "name": "Medium Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point", "description": "Medium Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Tap", "code": 80 }, { "name": "Overhead Splice", "code": 81 }, { "name": "Overhead Tap", "code": 82 }, { "name": "Underground Solid Connection", "code": 83 }, { "name": "Underground Splice", "code": 84 }, { "name": "Neutral Connection", "code": 85 }, { "name": "Overhead Solid Connection", "code": 86 }, { "name": "Underground Phase Connector", "code": 87 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 8, "name": "Medium Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Line_End", "description": "Medium Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Terminator", "code": 160 }, { "name": "Overhead Line End", "code": 161 }, { "name": "Underground Terminator", "code": 162 }, { "name": "Overhead Wire Change", "code": 163 }, { "name": "Underground Wire Change", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 9, "name": "Medium Voltage Line End" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Attachment", "description": "Low Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 101 }, { "name": "AC Underground", "code": 102 }, { "name": "DC Overhead", "code": 103 }, { "name": "DC Underground", "code": 104 }, { "name": "AC Riser", "code": 105 }, { "name": "DC Riser", "code": 106 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 4, "name": "Low Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Connection_Point", "description": "Low Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 120 }, { "name": "DC Overhead Splice", "code": 121 }, { "name": "AC Busbar Tap", "code": 124 }, { "name": "DC Busbar Tap", "code": 125 }, { "name": "AC Underground Splice", "code": 126 }, { "name": "DC Underground Splice", "code": 127 }, { "name": "AC Overhead Tap", "code": 128 }, { "name": "DC Overhead Tap", "code": 129 }, { "name": "AC Underground Solid Connection", "code": 130 }, { "name": "DC Underground Solid Connection", "code": 131 }, { "name": "AC Overhead Solid Connection", "code": 132 }, { "name": "DC Overhead Solid Connection", "code": 133 }, { "name": "AC Underground Phase Connector", "code": 134 }, { "name": "DC Underground Phase Connector", "code": 135 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 5, "name": "Low Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Line_End", "description": "Low Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Line End", "code": 141 }, { "name": "DC Overhead Line End", "code": 142 }, { "name": "AC Underground Terminator", "code": 143 }, { "name": "DC Underground Terminator", "code": 144 }, { "name": "AC Overhead Wire Change", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "id": 6, "name": "Low Voltage Line End" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "UtilityNetworkElectric_6_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": null, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Attachment", "description": "High Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "DC Overhead", "code": 3 }, { "name": "DC Underground", "code": 4 }, { "name": "AC Riser", "code": 5 }, { "name": "DC Riser", "code": 6 }, { "name": "AC Submersible", "code": 7 }, { "name": "DC Submersible", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 1, "name": "High Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Connection_Point", "description": "High Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 20 }, { "name": "AC Tap", "code": 21 }, { "name": "DC Overhead Splice", "code": 22 }, { "name": "DC Tap", "code": 23 }, { "name": "AC Busbar Tap", "code": 24 }, { "name": "DC Busbar Tap", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 2, "name": "High Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Line_End", "description": "High Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 41 }, { "name": "DC Overhead", "code": 42 }, { "name": "AC Busbar Terminator", "code": 45 }, { "name": "DC Busbar Terminator", "code": 46 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "34.5 kV", "code": 34500 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 3, "name": "High Voltage Line End" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Attachment", "description": "Medium Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead", "code": 60 }, { "name": "Underground", "code": 61 }, { "name": "Riser", "code": 62 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 7, "name": "Medium Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point", "description": "Medium Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Tap", "code": 80 }, { "name": "Overhead Splice", "code": 81 }, { "name": "Overhead Tap", "code": 82 }, { "name": "Underground Solid Connection", "code": 83 }, { "name": "Underground Splice", "code": 84 }, { "name": "Neutral Connection", "code": 85 }, { "name": "Overhead Solid Connection", "code": 86 }, { "name": "Underground Phase Connector", "code": 87 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 8, "name": "Medium Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Line_End", "description": "Medium Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Terminator", "code": 160 }, { "name": "Overhead Line End", "code": 161 }, { "name": "Underground Terminator", "code": 162 }, { "name": "Overhead Wire Change", "code": 163 }, { "name": "Underground Wire Change", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 9, "name": "Medium Voltage Line End" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Attachment", "description": "Low Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 101 }, { "name": "AC Underground", "code": 102 }, { "name": "DC Overhead", "code": 103 }, { "name": "DC Underground", "code": 104 }, { "name": "AC Riser", "code": 105 }, { "name": "DC Riser", "code": 106 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 4, "name": "Low Voltage Attachment" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Connection_Point", "description": "Low Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 120 }, { "name": "DC Overhead Splice", "code": 121 }, { "name": "AC Busbar Tap", "code": 124 }, { "name": "DC Busbar Tap", "code": 125 }, { "name": "AC Underground Splice", "code": 126 }, { "name": "DC Underground Splice", "code": 127 }, { "name": "AC Overhead Tap", "code": 128 }, { "name": "DC Overhead Tap", "code": 129 }, { "name": "AC Underground Solid Connection", "code": 130 }, { "name": "DC Underground Solid Connection", "code": 131 }, { "name": "AC Overhead Solid Connection", "code": 132 }, { "name": "DC Overhead Solid Connection", "code": 133 }, { "name": "AC Underground Phase Connector", "code": 134 }, { "name": "DC Underground Phase Connector", "code": 135 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 5, "name": "Low Voltage Connection Point" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Line_End", "description": "Low Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Line End", "code": 141 }, { "name": "DC Overhead Line End", "code": 142 }, { "name": "AC Underground Terminator", "code": 143 }, { "name": "DC Underground Terminator", "code": 144 }, { "name": "AC Overhead Wire Change", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "CREATIONDATE": null, "CREATOR": null, "LASTUPDATE": null, "UPDATEDBY": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "x_coordinate": null, "y_coordinate": null }, "code": 6, "name": "Low Voltage Line End" } ], "relationships": [ { "id": 42, "name": "ElectricCableMountDetail", "relatedTableId": 172, "role": "esriRelRoleOrigin", "keyField": "globalid", "cardinality": "esriRelCardinalityOneToMany", "composite": false, "catalogID": "{17DE6B06-1348-4C1C-9C2A-00B107F4097A}" }, { "id": 43, "name": "StructureMountDetail", "relatedTableId": 172, "role": "esriRelRoleOrigin", "keyField": "globalid", "cardinality": "esriRelCardinalityOneToMany", "composite": false, "catalogID": "{62BD1889-DDDB-40D4-ADF5-A8BC109F5442}" } ], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "maxSelectionCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsAdvancedQueryRelated": true, "supportsQueryRelatedPagination": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false, "supportsCurrentUserQueries": true }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Central Standard Time", "timeZoneIANA": "America/Chicago", "respectsDaylightSaving": true }, "preferredTimeReference": null, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1658997290000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true, "serviceItemId": "1bb7df369ca44c8880d65011fa3d69e6" }