Name: Electric Device Unit Table
Display Field: supportedsubnetworkname
Type: Table
Geometry Type: N/A
Description: null
Service Item Id: 1bb7df369ca44c8880d65011fa3d69e6
Copyright Text: null
Default Visibility: false
MaxRecordCount: 2000
MaxSelectionCount: 0
Supported Query Formats: JSON, PBF
Supports Advanced Queries: true
Supports Statistics: true
Use Standardized Queries: true
Extent:
Drawing Info:
Feature Draw Order:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: false
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
Supports Percentile Statistics: true
Supports Having Clause: true
Supports Count Distinct: true
Supports Time Relation: true
Supports Sql Format: false
Supports Query Analytic: false
Supports Query With Current User: true
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeNone
Type ID Field: ASSETGROUP
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: Object ID
)
-
assetgroup
(
type: esriFieldTypeInteger, alias: Asset group
)
-
assettype
(
type: esriFieldTypeSmallInteger, alias: Asset type
)
-
creationdate
(
type: esriFieldTypeDate, alias: Creation date, length: 8
)
-
creator
(
type: esriFieldTypeString, alias: Creator, length: 255
)
-
lastupdate
(
type: esriFieldTypeDate, alias: Last update, length: 8
)
-
updatedby
(
type: esriFieldTypeString, alias: Updated by, length: 255
)
-
globalid
(
type: esriFieldTypeGlobalID, alias: Global ID, length: 38
)
-
supportedsubnetworkname
(
type: esriFieldTypeString, alias: Supported subnetwork name, length: 2000
)
-
supportingsubnetworkname
(
type: esriFieldTypeString, alias: Supporting subnetwork name, length: 2000
)
-
assetid
(
type: esriFieldTypeString, alias: Asset ID, length: 64
)
-
plandevicestatus
(
type: esriFieldTypeSmallInteger, alias: Planning Device Status
, Coded Values:
[0: Unknown]
, [1: Open]
, [2: Closed]
, ...1 more...
)
-
normaldevicestatus
(
type: esriFieldTypeSmallInteger, alias: Normal Device Status
, Coded Values:
[0: Unknown]
, [1: Open]
, [2: Closed]
, ...1 more...
)
-
currentdevicestatus
(
type: esriFieldTypeSmallInteger, alias: Devices Status
, Coded Values:
[0: Unknown]
, [1: Open]
, [2: Closed]
, ...1 more...
)
-
winterdevicestatus
(
type: esriFieldTypeSmallInteger, alias: Winter Status
, Coded Values:
[0: Unknown]
, [1: Open]
, [2: Closed]
, ...1 more...
)
-
summerdevicestatus
(
type: esriFieldTypeSmallInteger, alias: Summer Status
, Coded Values:
[0: Unknown]
, [1: Open]
, [2: Closed]
, ...1 more...
)
-
phasesnormal
(
type: esriFieldTypeSmallInteger, alias: Phases Normal
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasescurrent
(
type: esriFieldTypeSmallInteger, alias: User Assigned Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasessummer
(
type: esriFieldTypeSmallInteger, alias: Summer Configuration Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phaseswinter
(
type: esriFieldTypeSmallInteger, alias: Winter Configuration Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasesplan
(
type: esriFieldTypeSmallInteger, alias: Planned Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasesenergized
(
type: esriFieldTypeSmallInteger, alias: Phases Energized
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasessubstituted
(
type: esriFieldTypeInteger, alias: Phases Substituted
)
-
phasefrequency
(
type: esriFieldTypeSmallInteger, alias: Phase Frequency
, Coded Values:
[0: Unknown]
, [50: 50 hz]
, [60: 60 hz]
)
-
numphasesconstructed
(
type: esriFieldTypeSmallInteger, alias: Num Phases Built
, Coded Values:
[0: Unknown]
, [1: Single Phase]
, [2: Two Phase]
, ...1 more...
)
-
designtype
(
type: esriFieldTypeSmallInteger, alias: Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt
)
-
grounding
(
type: esriFieldTypeSmallInteger, alias: Grounding
, Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...2 more...
)
-
manufacturer
(
type: esriFieldTypeSmallInteger, alias: Manufacturer
, Coded Values:
[0: Unknown]
, [1: ABB/Westinghouse]
, [2: American Electric Lighting]
, ...56 more...
)
-
nominalvoltage
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-L)
, Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...39 more...
)
-
maxvoltage
(
type: esriFieldTypeInteger, alias: Maximum Voltage
, Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...23 more...
)
-
maxoperatingvoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
, Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...39 more...
)
-
compatibleunit
(
type: esriFieldTypeString, alias: Compatible Unit Code, length: 255
)
-
lifecyclestatus
(
type: esriFieldTypeSmallInteger, alias: Lifecycle Status
, Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...15 more...
)
-
model
(
type: esriFieldTypeString, alias: Device Model, length: 255
)
-
loadtapchangermaximumchange
(
type: esriFieldTypeDouble, alias: Load Tap Changer Maximum Change
)
-
loadtapchangerlowerbandwidth
(
type: esriFieldTypeDouble, alias: Load Tap Changer Lower Bandwidth
)
-
maximumboost
(
type: esriFieldTypeDouble, alias: Maximum Voltage Boost
)
-
z0psimpedance
(
type: esriFieldTypeDouble, alias: Sequence Impedance -Z0ps
)
-
z0xmimpedance
(
type: esriFieldTypeDouble, alias: Sequence Impedance -Z0xm
)
-
z1psimpedance
(
type: esriFieldTypeDouble, alias: Sequence Impedance -Z1ps
)
-
x0r0impedance
(
type: esriFieldTypeDouble, alias: R0pm, Sequence Impedance -X0
)
-
x1r1impedance
(
type: esriFieldTypeDouble, alias: R1, Sequence Impedance -X1
)
-
z0pmimpedance
(
type: esriFieldTypeDouble, alias: Sequence Impedance -Z0pm
)
-
primarygroundimpedance
(
type: esriFieldTypeDouble, alias: Inductance/Impedance
)
-
gridsidecouplinginductance
(
type: esriFieldTypeDouble, alias: Inductance/Impedance
)
-
remotecontrollerindicator
(
type: esriFieldTypeSmallInteger, alias: Remote Control Indicator
)
-
equipmentyype
(
type: esriFieldTypeSmallInteger, alias: Group/Type
)
-
tripmode
(
type: esriFieldTypeSmallInteger, alias: Single Phase Trip and Lockout
)
-
tapsandpoles
(
type: esriFieldTypeSmallInteger, alias: Number of Poles, Number of Taps
)
-
nominalvoltagelg
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-G)
, Coded Values:
[0: Unknown]
, [120: 120 V]
, [240: 240 V]
, ...10 more...
)
-
directional
(
type: esriFieldTypeSmallInteger, alias: Bi Directional/Reversible
)
-
peakload
(
type: esriFieldTypeInteger, alias: Max Reactive Power, Peak Generation, Peak Load
)
-
offpeakload
(
type: esriFieldTypeInteger, alias: Min Reactive Power, Normal Generation, Off Peak Load
)
-
district
(
type: esriFieldTypeString, alias: District, length: 255
)
-
installdate
(
type: esriFieldTypeDate, alias: Install Date, length: 8
)
-
retireddate
(
type: esriFieldTypeDate, alias: Retired Date, length: 8
)
-
inservicedate
(
type: esriFieldTypeDate, alias: In-Service Date, length: 8
)
-
isvalidloop
(
type: esriFieldTypeSmallInteger, alias: Is Loop Valid
, Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
)
-
ownedby
(
type: esriFieldTypeSmallInteger, alias: Owned by
, Coded Values:
[1: Our Agency]
, [2: Private]
, [100: Other]
, ...1 more...
)
-
maintby
(
type: esriFieldTypeSmallInteger, alias: Maintained By
, Coded Values:
[1: Our Agency]
, [2: Private]
, [100: Other]
)
-
notes
(
type: esriFieldTypeString, alias: General Notes, length: 2000
)
-
devicestate
(
type: esriFieldTypeSmallInteger, alias: Device State
)
-
upperrange
(
type: esriFieldTypeDouble, alias: Upper Tempature Range - Operating
)
-
upperrangemetric
(
type: esriFieldTypeDouble, alias: Upper Tempature Range - Operating (Metric)
)
-
lowerrange
(
type: esriFieldTypeDouble, alias: Lower Tempature Range - Operating
)
-
lowerrangemetric
(
type: esriFieldTypeDouble, alias: Lower Tempature Range - Operating (Metric)
)
-
primarygroundimpedance2
(
type: esriFieldTypeDouble, alias: Inductance/Impedance
)
-
reversetrip
(
type: esriFieldTypeSmallInteger, alias: Reverse Trip
, Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
)
-
p2sphaseshift
(
type: esriFieldTypeSmallInteger, alias: Phase Shift/Phase Angle
, Range: [-30, 30]
)
-
p2tphaseshift
(
type: esriFieldTypeSmallInteger, alias: Master Angle, Primary to Tertiary Phase Shift
, Range: [-30, 30]
)
-
timedelay
(
type: esriFieldTypeSmallInteger, alias: Trip Time Delay
, Range: [0, 10]
)
-
tripcount
(
type: esriFieldTypeSmallInteger, alias: Lockout Trip Count
, Range: [0, 5]
)
-
tapmaxchange
(
type: esriFieldTypeSmallInteger, alias: Over Current % Rated, Tap Maximum Change
, Range: [-15, 15]
)
-
secondaryvoltagelinetoline
(
type: esriFieldTypeInteger, alias: Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage Line To Line
, Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...39 more...
)
-
secondaryvoltagelinetoground
(
type: esriFieldTypeInteger, alias: Secondary Voltage Line To Ground
, Coded Values:
[0: Unknown]
, [120: 120 V]
, [240: 240 V]
, ...10 more...
)
-
tertiaryvoltagelinetoline
(
type: esriFieldTypeInteger, alias: Tertiary Voltage Line To Line
, Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...39 more...
)
-
tertiaryvoltagelinetoground
(
type: esriFieldTypeInteger, alias: Tertiary Voltage Line To Ground
, Coded Values:
[0: Unknown]
, [120: 120 V]
, [240: 240 V]
, ...10 more...
)
-
optype
(
type: esriFieldTypeSmallInteger, alias: Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type
)
-
validationstatus
(
type: esriFieldTypeSmallInteger, alias: Validation status
)
-
maximumpower
(
type: esriFieldTypeInteger, alias: Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR
)
-
minimumpower
(
type: esriFieldTypeInteger, alias: DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching impulse discharge current (Amps)
)
-
ratedpower
(
type: esriFieldTypeInteger, alias: AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR
)
-
loadtapchangepercent
(
type: esriFieldTypeSmallInteger, alias: Load Tap Change (%)
, Range: [-15, 15]
)
-
noloadloss
(
type: esriFieldTypeInteger, alias: Losses, No Load Loss
)
-
secondarygroundimpedance
(
type: esriFieldTypeDouble, alias: Secondary Ground Impedance
)
-
ctratio
(
type: esriFieldTypeInteger, alias: CT Ratio
)
-
ptratio
(
type: esriFieldTypeInteger, alias: PT Ratio
)
-
maximumbuck
(
type: esriFieldTypeDouble, alias: Maximum Buck, Stator or Rotor Impedance
)
-
secondarygroundimpedance2
(
type: esriFieldTypeDouble, alias: Secondary Ground Impedance
)
-
buckbandwidth
(
type: esriFieldTypeSmallInteger, alias: Buck Bandwidth
)
-
loadtapchangerupperbandwidth
(
type: esriFieldTypeDouble, alias: Diameter/Width
)
-
loadtapchangerminimumchange
(
type: esriFieldTypeDouble, alias: LTC - Minimum Range, Load Tap Changer Minimum Change
)
-
starthour
(
type: esriFieldTypeSmallInteger, alias: Start Hour of Operation
)
-
stophour
(
type: esriFieldTypeSmallInteger, alias: Stop Hour of Operation
)
-
powerfactor
(
type: esriFieldTypeDouble, alias: Power Factor
)
-
coolingtype
(
type: esriFieldTypeSmallInteger, alias: Cooling Type
)
-
relateddevice
(
type: esriFieldTypeGUID, alias: Related GUID, length: 38
)
Types:
ID: 0
Name: Unknown
Domains:
-
assettype:
Coded Values:
[0: Unknown]
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
ownedby:
Inherited
-
maintby:
Inherited
ID: 1
Name: Ground
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [1: Bound]
, [2: Rod]
, ...2 more...
-
designtype:
Coded Values:
[0: Unknown]
, [1: Bound]
, [2: Mesh]
, ...1 more...
-
manufacturer:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
primarygroundimpedance:
Range: [0, 5000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
optype:
Coded Values:
[0: Unknown]
, [515: Aluminum]
, [525: Copper]
ID: 2
Name: High Voltage Arrester
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [21: Indoor Arrester]
, [22: Line Arrester]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
designtype:
Coded Values:
[0: Unknown]
, [1: Intermediate]
, [3: Station]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
secondaryvoltagelinetoline:
Range: [100000, 750000]
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
-
minimumpower:
Range: [10, 10000]
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
ID: 3
Name: High Voltage Control Unit
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [41: Capacitor]
, [42: Switch and Breaker]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
designtype:
Coded Values:
[0: Unknown]
, [1: Normal Reclose]
, [2: Remote Block]
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
ID: 4
Name: High Voltage Generation
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [61: Battery]
, [62: Biomass]
, ...8 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
designtype:
Coded Values:
[0: Unknown]
, [1: Fixed]
, [2: Voltage]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [2: Group 2]
, [3: Group 3]
, ...2 more...
-
tapsandpoles:
Coded Values:
[0: Unknown]
, [2: 2 Pole]
, [4: 4 Pole]
, ...9 more...
-
peakload:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
offpeakload:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
p2sphaseshift:
Range: [-180, 180]
-
optype:
Coded Values:
[0: Unknown]
, [1: Ethenaol]
, [2: Gasoline]
, ...3 more...
-
maximumpower:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
minimumpower:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
ratedpower:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
powerfactor:
Range: [0, 1]
ID: 5
Name: High Voltage Line Monitor and Relay
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [80: Fault Indicator]
, [81: Instrument Transformer]
, ...2 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Analog]
, [2: Digital]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 180]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
ID: 6
Name: High Voltage Power Conversion
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [101: Inverter]
, [102: Rectifier]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
primarygroundimpedance:
Range: [0, 999999]
-
gridsidecouplinginductance:
Range: [0, 999999]
-
peakload:
Coded Values:
[0: Unknown]
-
offpeakload:
Coded Values:
[0: Unknown]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [18000: 18 kV]
, [50000: 50 kV]
, ...37 more...
-
minimumpower:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
-
ratedpower:
Coded Values:
[-1: Idle]
, [0: Unknown]
, [540: 540 MW]
, ...1 more...
ID: 7
Name: High Voltage Power Factor Correcting
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [121: AC Capacitor]
, [122: AC Wave Trap]
, ...3 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
designtype:
Coded Values:
[0: Unknown]
, [1: Shunt]
, [2: Series]
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
primarygroundimpedance:
Range: [0, 999999]
-
gridsidecouplinginductance:
Range: [0, 999999]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: kVA-PF]
, [2: AMP-PF]
, ...1 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
secondaryvoltagelinetoline:
Range: [0, 15000]
-
optype:
Coded Values:
[0: Unknown]
, [1: Current]
, [2: Manual]
, ...5 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [50000: 50 kvar]
, [100000: 100 kvar]
, ...5 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [50000: 50 kvar]
, [100000: 100 kvar]
, ...5 more...
-
noloadloss:
Range: [0, 1000]
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
ID: 8
Name: High Voltage Regulator
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [141: AC Single Phase]
, [142: AC Three Phase]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tapsandpoles:
Range: [0, 32]
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Fixed Tap]
, [2: Regulator Terminal]
, ...2 more...
-
maximumpower:
Coded Values:
[0: Unknown]
-
ratedpower:
Coded Values:
[0: Unknown]
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
maximumbuck:
Range: [0, 20]
-
buckbandwidth:
Range: [-5000, 5000]
-
loadtapchangerupperbandwidth:
Range: [0, 20]
-
loadtapchangerminimumchange:
Range: [0, 20]
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
-
powerfactor:
Range: [0, 1]
-
coolingtype:
Coded Values:
[0: Unknown]
, [1: Air Natural (AN)]
, [2: Air Blast]
, ...4 more...
ID: 9
Name: High Voltage Service
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [161: AC Metering]
, [162: DC Metering]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
peakload:
Range: [0, 500000]
-
offpeakload:
Range: [0, 500000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
noloadloss:
Range: [0, 1000]
ID: 10
Name: High Voltage Switch
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [181: AC Circuit Breaker]
, [182: AC Disconnect]
, ...7 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Coded Values:
[0: Unknown]
, [1: ABB/Westinghouse]
, [16: G&W Electric]
, ...15 more...
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tripmode:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
maximumpower:
Range: [0, 15000]
-
minimumpower:
Coded Values:
[0: Unknown]
, [600: 600 Amps]
, [1200: 1200 Amps]
, ...3 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [31500: 31.5 kA]
, [40000: 40 kA]
, ...3 more...
ID: 11
Name: High Voltage Transformer
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [201: AC Single Phase Power]
, [202: AC Three Phase Power]
, ...2 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...1 more...
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
tapsandpoles:
Range: [0, 32]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
primarygroundimpedance2:
Range: [0, 5000]
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
tapmaxchange:
Inherited
-
secondaryvoltagelinetoline:
Inherited
-
secondaryvoltagelinetoground:
Inherited
-
tertiaryvoltagelinetoline:
Inherited
-
tertiaryvoltagelinetoground:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [5500000: 5.5 mVA]
, [74000000: 74 mVA]
-
ratedpower:
Coded Values:
[0: Unknown]
, [5500000: 5.5 mVA]
, [74000000: 74 mVA]
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 1000]
-
secondarygroundimpedance:
Range: [0, 5000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
secondarygroundimpedance2:
Range: [0, 5000]
-
loadtapchangerupperbandwidth:
Range: [0, 10]
-
loadtapchangerminimumchange:
Range: [0, 20]
-
powerfactor:
Range: [0, 1]
-
coolingtype:
Coded Values:
[0: Unknown]
, [1: Air Natural (AN)]
, [2: Air Blast]
, ...4 more...
ID: 25
Name: Medium Voltage Arrester
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [481: Elbow Arrester]
, [482: Line Arrester]
, ...1 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Load Break]
, [2: Surge]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
secondaryvoltagelinetoline:
Range: [8000, 118000]
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
ID: 26
Name: Medium Voltage Circuit Breaker
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [361: Network Protector]
, [501: Isolator Switch]
, ...2 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [-180, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Air]
, [2: CO2]
, ...4 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [250: 250 Amps]
, [500: 500 Amps]
, ...10 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
ID: 27
Name: Medium Voltage Control Unit
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [521: Capacitor]
, [522: Circuit Breaker]
, ...3 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Normal Reclose]
, [2: Remote Block]
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
ID: 28
Name: Medium Voltage Elbow
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [541: Load Break Feedthru]
, [542: Load Break Junction]
, ...4 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [250: 250 Amps]
, [500: 500 Amps]
, ...10 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
ID: 29
Name: Medium Voltage Fuse
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [561: Bayonet]
, [562: Fault Limiter]
, ...9 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: C]
, [2: E]
, ...2 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Bridged]
, [2: Burndy]
, ...16 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [250: 250 Amps]
, [500: 500 Amps]
, ...10 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
ID: 30
Name: Medium Voltage Generation
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [61: Battery]
, [62: Biomass]
, ...7 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Fixed]
, [2: Voltage]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
equipmentyype:
Coded Values:
[0: Unknown]
, [2: Group 2]
, [3: Group 3]
, ...2 more...
-
tapsandpoles:
Coded Values:
[0: Unknown]
, [2: 2 Pole]
, [4: 4 Pole]
, ...9 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
optype:
Coded Values:
[0: Unknown]
, [1: Ethenaol]
, [2: Gasoline]
, ...3 more...
-
powerfactor:
Range: [0, 1]
ID: 31
Name: Medium Voltage Line Monitor and Relay
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [601: Fault Indicator]
, [602: Instrument Transformer]
, ...5 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Analog]
, [2: Digital]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
powerfactor:
Range: [0, 1]
ID: 32
Name: Medium Voltage Motor and Pump
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [621: Single Phase Motor]
, [622: Single Phase Pump]
, ...2 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Induction]
, [2: Synchronous]
-
grounding:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
equipmentyype:
Coded Values:
[0: Unknown]
, [2: Group 2]
, [3: Group 3]
, ...2 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
optype:
Coded Values:
[0: Unknown]
, [1: Auto Transformer]
, [2: Capacitor]
, ...4 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
powerfactor:
Range: [0, 1]
ID: 33
Name: Medium Voltage Power Conversion
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [412: Wave Trap]
, [641: Single Phase Inverter]
, ...3 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
primarygroundimpedance:
Range: [0, 999999]
-
gridsidecouplinginductance:
Range: [0, 999999]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Coded Values:
[0: Unknown]
-
offpeakload:
Coded Values:
[0: Unknown]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [12: 12 V]
, [24: 24 V]
, ...16 more...
-
maximumpower:
Range: [0, 100000]
-
minimumpower:
Range: [0, 100000]
-
ratedpower:
Range: [0, 100000]
-
powerfactor:
Range: [0, 1]
ID: 34
Name: Medium Voltage Power Factor Correcting
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [401: Mobile Harmonic Filter]
, [402: Mobile Reactor]
, ...12 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Shunt]
, [2: Series]
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: kVA-PF]
, [2: AMP-PF]
, ...1 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
optype:
Coded Values:
[0: Unknown]
, [1: Current]
, [2: Manual]
, ...5 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [5000: 5 kvar]
, [10000: 10 kvar]
, ...11 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [5000: 5 kvar]
, [10000: 10 kvar]
, ...11 more...
-
noloadloss:
Range: [0, 1000]
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
-
powerfactor:
Range: [0, 1]
ID: 35
Name: Medium Voltage Regulator
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [681: Overhead Single Phase VR]
, [683: Overhead Three Phase VR]
, ...2 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
tapsandpoles:
Range: [0, 32]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 32]
-
optype:
Coded Values:
[0: Unknown]
, [1: Fixed Tap]
, [2: Regulator Terminal]
, ...2 more...
-
maximumpower:
Coded Values:
[0: Unknown]
-
ratedpower:
Coded Values:
[0: Unknown]
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
maximumbuck:
Range: [0, 20]
-
buckbandwidth:
Range: [-5000, 5000]
-
loadtapchangerupperbandwidth:
Range: [0, 10]
-
loadtapchangerminimumchange:
Range: [0, 10]
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
ID: 36
Name: Medium Voltage Service
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [701: Primary Meter - Industrial Customer]
, [702: Primary Meter - Utility Customer]
, ...1 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Range: [0, 100000]
-
offpeakload:
Range: [0, 100000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
ratedpower:
Range: [0, 100000]
-
noloadloss:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
ID: 41
Name: Medium Voltage Recloser
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [730: Overhead Single Phase Recloser]
, [744: Overhead Three Phase Recloser]
, ...2 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
ID: 42
Name: Medium Voltage Sectionalizer
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [731: Overhead Single Phase Sectionalizer]
, [745: Overhead Three Phase Sectionalizer]
, ...2 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
ID: 37
Name: Medium Voltage Switch
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [721: Cabinet Bypass]
, [722: Cabinet Switch]
, ...21 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Coded Values:
[0: Unknown]
, [1: ABB/Westinghouse]
, [16: G&W Electric]
, ...15 more...
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [2: No]
, [4: All Phases]
, ...1 more...
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Air]
, [2: CO2]
, ...4 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [250: 250 Amps]
, [500: 500 Amps]
, ...10 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...26 more...
ID: 38
Name: Medium Voltage Transformer
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [781: Grounding Transformer]
, [782: Mobile Single Phase]
, ...12 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
tapsandpoles:
Range: [0, 32]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Range: [0, 100000]
-
offpeakload:
Range: [0, 100000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
primarygroundimpedance2:
Range: [0, 5000]
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
secondaryvoltagelinetoground:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
tertiaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
tertiaryvoltagelinetoground:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [1000: 1.0 kVA]
, ...64 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [1000: 1.0 kVA]
, ...64 more...
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 1000]
-
secondarygroundimpedance:
Range: [0, 5000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
secondarygroundimpedance2:
Range: [0, 5000]
-
coolingtype:
Coded Values:
[0: Unknown]
, [1: Air Natural (AN)]
, [2: Air Blast]
, ...4 more...
ID: 39
Name: Medium Voltage Step Transformer
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [801: Overhead Step Down Single Phase]
, [802: Overhead Step Down Three Phase]
, ...10 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
tapsandpoles:
Range: [0, 32]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
peakload:
Range: [0, 100000]
-
offpeakload:
Range: [0, 100000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
primarygroundimpedance2:
Range: [0, 5000]
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
secondaryvoltagelinetoground:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
tertiaryvoltagelinetoline:
Inherited
-
tertiaryvoltagelinetoground:
Inherited
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [1000: 1.0 kVA]
, ...64 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [1000: 1.0 kVA]
, ...64 more...
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 1000]
-
secondarygroundimpedance:
Range: [0, 5000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
secondarygroundimpedance2:
Range: [0, 5000]
-
coolingtype:
Coded Values:
[0: Unknown]
, [1: Air Natural (AN)]
, [2: Air Blast]
, ...4 more...
ID: 40
Name: Low Voltage Circuit Breaker
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [471: AC Circuit Breaker]
, [472: DC Circuit Breaker]
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Air]
, [2: CO2]
, ...4 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [30: 30 Amps]
, [60: 60 Amps]
, ...3 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
ID: 12
Name: Low Voltage Arrester
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [221: Overhead Arrester]
, [222: Underground Arrester]
, ...2 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Load Break]
, [2: Surge]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: .5 kA]
, [1000: 1 kA]
, ...8 more...
ID: 13
Name: Low Voltage Control Unit
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [241: Control Unit]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Normal Reclose]
, [2: Remote Block]
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
-
powerfactor:
Range: [0, 1]
ID: 14
Name: Low Voltage Fuse
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [261: AC Overhead]
, [262: AC Underground]
, ...2 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [17: Kearney A]
, [18: Kearney B]
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
optype:
Coded Values:
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [30: 30 Amps]
, [60: 60 Amps]
, ...3 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
ID: 15
Name: Low Voltage Generation
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [61: Battery]
, [282: Car Charger]
, ...3 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Fixed]
, [2: Voltage]
, ...1 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [2: Group 2]
, [3: Group 3]
, ...2 more...
-
tapsandpoles:
Coded Values:
[0: Unknown]
, [2: 2 Pole]
, [4: 4 Pole]
, ...9 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
optype:
Coded Values:
[0: Unknown]
, [1: Ethenaol]
, [2: Gasoline]
, ...3 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
powerfactor:
Range: [0, 1]
ID: 16
Name: Low Voltage Lighting
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [301: Flood light]
, [302: Streetlight]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Cobra Head]
, [2: Security]
, ...2 more...
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
optype:
Coded Values:
[0: Unknown]
, [30: High Pressure Sodium (HPS)]
, [31: Low Pressure Sodium (LPS)]
, ...6 more...
ID: 17
Name: Low Voltage Line Monitor and Relay
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [321: Fault Indicator]
, [322: Load Monitor]
, ...2 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Analog]
, [2: Digital]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
reversetrip:
Inherited
-
p2sphaseshift:
Range: [0, 180]
-
p2tphaseshift:
Range: [0, 180]
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Range: [0, 100]
-
secondaryvoltagelinetoline:
Range: [0, 1000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
powerfactor:
Range: [0, 1]
ID: 18
Name: Low Voltage Motor
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [341: Single Phase Motor]
, [342: Three Phase Motor]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Induction]
, [2: Synchronous]
-
grounding:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [2: Group 2]
, [3: Group 3]
, ...2 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
optype:
Coded Values:
[0: Unknown]
, [1: Auto Transformer]
, [2: Capacitor]
, ...4 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
powerfactor:
Range: [0, 1]
ID: 19
Name: Low Voltage Network Protection
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [361: Network Protector]
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [30: 30 Amps]
, [60: 60 Amps]
, ...3 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
ID: 20
Name: Low Voltage Power Conversion
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [381: Single Phase Inverter]
, [382: Single Phase Rectifier]
, ...2 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
primarygroundimpedance:
Range: [0, 999999]
-
gridsidecouplinginductance:
Range: [0, 999999]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [12: 12 V]
, [24: 24 V]
, ...16 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
powerfactor:
Range: [0, 1]
ID: 21
Name: Low Voltage Power Factor Correcting
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [401: Mobile Harmonic Filter]
, [402: Mobile Reactor]
, ...10 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
designtype:
Coded Values:
[0: Unknown]
, [1: Shunt]
, [2: Series]
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
gridsidecouplinginductance:
Range: [0, 999999]
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: kVA-PF]
, [2: AMP-PF]
, ...1 more...
-
tripmode:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
upperrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
upperrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
lowerrange:
Coded Values:
[0: 32 F]
, [75: 167 F]
, [90: 194 F]
, ...4 more...
-
lowerrangemetric:
Coded Values:
[0: 0 C]
, [75: 75 C]
, [90: 90 C]
, ...4 more...
-
optype:
Coded Values:
[0: Unknown]
, [1: Current]
, [2: Manual]
, ...5 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [25000: 25 kvar]
, [50000: 50 kvar]
, ...8 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [25000: 25 kvar]
, [50000: 50 kvar]
, ...8 more...
-
starthour:
Range: [1, 24]
-
stophour:
Range: [1, 24]
-
powerfactor:
Range: [0, 1]
ID: 22
Name: Low Voltage Service
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [421: Single Phase Commercial]
, [422: Single Phase Residential]
, ...4 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
peakload:
Range: [0, 10000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
ratedpower:
Range: [0, 10000]
-
noloadloss:
Range: [0, 100]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
powerfactor:
Range: [0, 1]
ID: 23
Name: Low Voltage Switch
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [441: Overhead AC Load Break]
, [442: Overhead AC Disconnect]
, ...14 more...
-
plandevicestatus:
Inherited
-
normaldevicestatus:
Inherited
-
currentdevicestatus:
Inherited
-
winterdevicestatus:
Inherited
-
summerdevicestatus:
Inherited
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Inherited
-
manufacturer:
Coded Values:
[0: Unknown]
, [1: ABB/Westinghouse]
, [16: G&W Electric]
, ...15 more...
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
remotecontrollerindicator:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
tripmode:
Coded Values:
[0: Unknown]
, [10: Trip Only]
, [11: Trip and Lockout]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
directional:
Coded Values:
[0: Unknown]
, [1: Yes]
, [2: No]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
reversetrip:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
optype:
Coded Values:
[0: Unknown]
, [1: Air]
, [2: CO2]
, ...4 more...
-
maximumpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
-
minimumpower:
Coded Values:
[0: Unknown]
, [30: 30 Amps]
, [60: 60 Amps]
, ...3 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [3: 3 Amps]
, [7: 7 Amps]
, ...9 more...
ID: 24
Name: Low Voltage Transformer
Domains:
-
assettype:
Coded Values:
[0: Unknown]
, [461: Single Phase]
, [462: Three Phase]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
grounding:
Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...1 more...
-
manufacturer:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
maxoperatingvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
loadtapchangermaximumchange:
Range: [0, 20]
-
loadtapchangerlowerbandwidth:
Range: [0, 10]
-
maximumboost:
Range: [-10, 10]
-
z0psimpedance:
Range: [0, 5000]
-
z0xmimpedance:
Range: [0, 5000]
-
z1psimpedance:
Range: [0, 5000]
-
x0r0impedance:
Range: [0, 5000]
-
x1r1impedance:
Range: [0, 5000]
-
z0pmimpedance:
Range: [0, 5000]
-
primarygroundimpedance:
Range: [0, 5000]
-
gridsidecouplinginductance:
Range: [0, 5000]
-
equipmentyype:
Coded Values:
[0: Unknown]
, [1: Dry]
, [2: Oil Filled]
, ...2 more...
-
tapsandpoles:
Range: [0, 32]
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
peakload:
Range: [0, 100000]
-
offpeakload:
Range: [0, 10000]
-
isvalidloop:
Inherited
-
ownedby:
Inherited
-
maintby:
Inherited
-
devicestate:
Coded Values:
[3: Active]
, [4: Inactive]
-
primarygroundimpedance2:
Range: [0, 5000]
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
secondaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
secondaryvoltagelinetoground:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
tertiaryvoltagelinetoline:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
tertiaryvoltagelinetoground:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
maximumpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
ratedpower:
Coded Values:
[0: Unknown]
, [500: 0.5 kVA]
, [750: 0.75 kVA]
, ...9 more...
-
loadtapchangepercent:
Inherited
-
noloadloss:
Range: [0, 100]
-
secondarygroundimpedance:
Range: [0, 5000]
-
ctratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
ptratio:
Coded Values:
[0: Unknown]
, [50: 50:5]
, [60: 60:5]
, ...21 more...
-
secondarygroundimpedance2:
Range: [0, 5000]
-
powerfactor:
Range: [0, 1]
-
coolingtype:
Coded Values:
[0: Unknown]
, [1: Air Natural (AN)]
, [2: Air Blast]
, ...4 more...
Relationships:
Supported Operations:
Query
Query Attachments
Query Analytic
Query Related Records
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata