Parent Layer:
Electric Junction
Name: Low Voltage Line End
Display Field: SUBNETWORKNAME
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: 1bb7df369ca44c8880d65011fa3d69e6
Copyright Text:
Default Visibility: true
MaxRecordCount: 2000
MaxSelectionCount: 2000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 300.0
Max Scale: 0.0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 1979712.4670004405
YMin: 174037.4177064687
XMax: 2144650.1300378432
YMax: 332896.29693689046
Spatial Reference: 102704
(26852)
VCSWkid(105703)
LatestVCSWkid(6360)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: ASSETTYPE
Field 2: N/A
Field 3: N/A
Field Delimiter: ,
Default Symbol:
Default Label: Other
UniqueValueInfos:
-
Value: 0
Label: Unknown
Description: N/A
Symbol:
-
Value: 141
Label: AC Overhead Line End
Description: N/A
Symbol:
-
Value: 142
Label: DC Overhead Line End
Description: N/A
Symbol:
-
Value: 143
Label: AC Underground Terminator
Description: N/A
Symbol:
-
Value: 144
Label: DC Underground Terminator
Description: N/A
Symbol:
-
Value: 145
Label: AC Overhead Wire Change
Description: N/A
Symbol:
Transparency: 0
Labeling Info:
Feature Draw Order:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
Supports Percentile Statistics: true
Supports Having Clause: true
Supports Count Distinct: true
Supports Time Relation: true
Supports Sql Format: false
Supports Query Analytic: false
Supports Query With Current User: true
HasZ: true
HasM: true
Has Attachments: true
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: ASSETGROUP
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: Object ID
)
-
ASSETGROUP
(
type: esriFieldTypeInteger, alias: Asset Group
)
-
ASSETTYPE
(
type: esriFieldTypeSmallInteger, alias: Asset Type
)
-
ASSOCIATIONSTATUS
(
type: esriFieldTypeSmallInteger, alias: Association status
, Coded Values:
[0: None]
, [1: Container]
, [2: Structure]
, ...33 more...
)
-
ISCONNECTED
(
type: esriFieldTypeSmallInteger, alias: Is connected
, Coded Values:
[0: False]
, [1: True]
, [2: Unknown]
)
-
CREATIONDATE
(
type: esriFieldTypeDate, alias: Creation date, length: 8
)
-
CREATOR
(
type: esriFieldTypeString, alias: Creator, length: 255
)
-
LASTUPDATE
(
type: esriFieldTypeDate, alias: Last update, length: 8
)
-
UPDATEDBY
(
type: esriFieldTypeString, alias: Updated by, length: 255
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: Shape
)
-
GLOBALID
(
type: esriFieldTypeGlobalID, alias: Global ID, length: 38
)
-
assetid
(
type: esriFieldTypeString, alias: Asset ID, length: 64
)
-
nominalvoltage
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-L)
, Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...39 more...
)
-
maxvoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage (L-L)
, Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...23 more...
)
-
nominalvoltagelg
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-G)
, Coded Values:
[0: Unknown]
, [120: 120 V]
, [240: 240 V]
, ...10 more...
)
-
phasesnormal
(
type: esriFieldTypeSmallInteger, alias: Phases Normal
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasescurrent
(
type: esriFieldTypeSmallInteger, alias: User Assigned Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasessummer
(
type: esriFieldTypeSmallInteger, alias: Summer Configuration Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phaseswinter
(
type: esriFieldTypeSmallInteger, alias: Winter Configuration Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasesplan
(
type: esriFieldTypeSmallInteger, alias: Planned Phases
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasesenergized
(
type: esriFieldTypeSmallInteger, alias: Phases Energized
, Coded Values:
[0: De-Energized]
, [1: C]
, [2: B]
, ...5 more...
)
-
phasessubstituted
(
type: esriFieldTypeInteger, alias: Phases Substituted
)
-
phasefrequency
(
type: esriFieldTypeSmallInteger, alias: Phase Frequency
, Coded Values:
[0: Unknown]
, [50: 50 hz]
, [60: 60 hz]
)
-
numphasesconstructed
(
type: esriFieldTypeSmallInteger, alias: Num Phases Built
, Coded Values:
[0: Unknown]
, [1: Single Phase]
, [2: Two Phase]
, ...1 more...
)
-
lifecyclestatus
(
type: esriFieldTypeSmallInteger, alias: Lifecycle Status
, Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...15 more...
)
-
installdate
(
type: esriFieldTypeDate, alias: Install Date, length: 8
)
-
retireddate
(
type: esriFieldTypeDate, alias: Retired Date, length: 8
)
-
inservicedate
(
type: esriFieldTypeDate, alias: In-Service Date, length: 8
)
-
manufacturer
(
type: esriFieldTypeSmallInteger, alias: Equipment Maker
, Coded Values:
[0: Unknown]
, [1: ABB/Westinghouse]
, [2: American Electric Lighting]
, ...56 more...
)
-
spatialsource
(
type: esriFieldTypeSmallInteger, alias: Spatial Source
, Coded Values:
[0: Unknown]
, [1: As-Built]
, [2: CAD]
, ...3 more...
)
-
spatialconfidence
(
type: esriFieldTypeSmallInteger, alias: Spatial Confidence
, Coded Values:
[0: Unknown]
, [1: High]
, [2: Medium]
, ...1 more...
)
-
grounding
(
type: esriFieldTypeSmallInteger, alias: System Grounding
, Coded Values:
[0: Unknown]
, [1: Grounded Wye]
, [2: Wye]
, ...2 more...
)
-
notes
(
type: esriFieldTypeString, alias: General Notes, length: 2000
)
-
symbolrotation
(
type: esriFieldTypeSmallInteger, alias: Symbol Rotation
, Range: [0, 359]
)
-
maintby
(
type: esriFieldTypeSmallInteger, alias: Maintained By
, Coded Values:
[1: Our Agency]
, [2: Private]
, [100: Other]
)
-
ownedby
(
type: esriFieldTypeSmallInteger, alias: Owned by
, Coded Values:
[1: Our Agency]
, [2: Private]
, [100: Other]
, ...1 more...
)
-
SUBNETWORKNAME
(
type: esriFieldTypeString, alias: Subnetwork name, length: 2000
)
-
SUPPORTEDSUBNETWORKNAME
(
type: esriFieldTypeString, alias: Supported subnetwork name, length: 2000
)
-
SUPPORTINGSUBNETWORKNAME
(
type: esriFieldTypeString, alias: Supporting subnetwork name, length: 2000
)
-
x_coordinate
(
type: esriFieldTypeSmallInteger, alias: Easting Bearing
)
-
y_coordinate
(
type: esriFieldTypeSmallInteger, alias: Northing Bearing
)
Types:
ID: 0
Name: Unknown
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 1
Name: High Voltage Attachment
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [1: AC Overhead]
, [2: AC Underground]
, ...6 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 2
Name: High Voltage Connection Point
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [20: AC Overhead Splice]
, [21: AC Tap]
, ...4 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 3
Name: High Voltage Line End
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [41: AC Overhead]
, [42: DC Overhead]
, ...2 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [34500: 34.5 kV]
, [115000: 115 kV]
, ...7 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [120000: 120 kV]
, [145000: 145 kV]
, ...9 more...
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: III]
, [2: II]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Coded Values:
[0: Unknown]
, [2: Two Phase]
, [3: Three Phase]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 7
Name: Medium Voltage Attachment
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [60: Overhead]
, [61: Underground]
, ...1 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 8
Name: Medium Voltage Connection Point
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [80: Busbar Tap]
, [81: Overhead Splice]
, ...6 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 9
Name: Medium Voltage Line End
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [160: Busbar Terminator]
, [161: Overhead Line End]
, ...3 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...20 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [8000: 8 kV]
, [15000: 15 kV]
, ...4 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [2400: 2.4 kV]
, [4800: 4.8 kV]
, ...8 more...
-
phasesnormal:
Inherited
-
phasescurrent:
Inherited
-
phasessummer:
Inherited
-
phaseswinter:
Inherited
-
phasesplan:
Inherited
-
phasesenergized:
Inherited
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 4
Name: Low Voltage Attachment
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [101: AC Overhead]
, [102: AC Underground]
, ...4 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 5
Name: Low Voltage Connection Point
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [120: AC Overhead Splice]
, [121: DC Overhead Splice]
, ...12 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
ID: 6
Name: Low Voltage Line End
Domains:
-
ASSETTYPE:
Coded Values:
[0: Unknown]
, [141: AC Overhead Line End]
, [142: DC Overhead Line End]
, ...3 more...
-
ASSOCIATIONSTATUS:
Inherited
-
ISCONNECTED:
Inherited
-
nominalvoltage:
Coded Values:
[0: Unknown]
, [208: 208 V]
, [240: 240 V]
, ...2 more...
-
maxvoltage:
Coded Values:
[0: Unknown]
, [229: 229 V]
, [253: 253 V]
, ...6 more...
-
nominalvoltagelg:
Coded Values:
[0: Unknown]
, [120: 120 V]
, [277: 277 V]
-
phasesnormal:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasescurrent:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasessummer:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phaseswinter:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesplan:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasesenergized:
Coded Values:
[0: De-Energized]
, [1: c]
, [2: b]
, ...5 more...
-
phasefrequency:
Inherited
-
numphasesconstructed:
Inherited
-
lifecyclestatus:
Coded Values:
[0: Unknown]
, [1: Proposed]
, [2: Approved]
, ...7 more...
-
manufacturer:
Inherited
-
spatialsource:
Inherited
-
spatialconfidence:
Inherited
-
grounding:
Inherited
-
symbolrotation:
Inherited
-
maintby:
Inherited
-
ownedby:
Inherited
Relationships:
Supported Operations:
Query
Query Attachments
Query Analytic
Query Related Records
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata